Construction measures applied to the elevator pit to prevent water ingress that could damage equipment or create electrical hazards.
Full Definition
Elevator pit waterproofing refers to the combination of civil works and drainage provisions that prevent water ingress into the pit from groundwater, surface drainage, or burst pipes. A flooded pit can damage buffer oil, contaminate hydraulic oil, corrode guide rail brackets, and create electrical short-circuit hazards. EN 81-20 requires drainage or collection provisions in pits susceptible to flooding. Waterproofing methods include: tanked waterproofing (crystalline coatings or bituminous membranes), drain channels and sump pits with water-level alarms, and sealed cable entries. The pit stop switch and electrical installations must be rated for wet conditions. Regular inspection of pit drainage is part of the maintenance schedule.