Elevator Fireman's Switch: Phase 1 Recall, Phase 2 Control and EN 81-72 Requirements

Glossary › Fireman's Switch (Fire Service Mode)

A key-operated building switch that recalls the elevator to the designated fire evacuation floor and gives exclusive control to emergency services.

Full Definition
The fireman's switch (or fire service operation) is activated by the building's fire alarm system or manually via a key switch at the designated fire service access level. Phase 1 operation recalls all elevators to the designated floor and holds doors open, allowing occupants to exit and firefighters to take control. Phase 2 gives a fire service officer exclusive control from inside the car, enabling access to any floor. EN 81-72 (Firefighters lifts) defines full requirements including dedicated shaft, power supply, car dimensions, and communication. Standard elevators with a fireman's switch must comply with the relevant national building code for Phase 1/2 operation.
Back to Glossary
Term
Fireman's Switch (Fire Service Mode)
Usage Area
All passenger elevators in multi-storey buildings firefighter lifts (EN 81-72) hospitals high-rise towers