A compact loudspeaker unit installed in the elevator cabin ceiling or COP panel area to reproduce floor arrival announcements, background music, emergency voice instructions, and intercom audio.
Full Definition
Elevator cabin speakers serve several functions: accessibility voice announcements (floor number, direction, door status — required by EN 81-70 for accessible lifts), emergency communication (two-way voice via the alarm intercom per EN 81-20 Section 14.2.3), and optional background music or building announcement relay. Ceiling speakers are typically 2–4 inch full-range drivers (5–15 W, 4 or 8 Ω) flush-mounted in the false ceiling with grille covers. Amplifier modules are located in the cabin junction box or integrated into the controller. Audio input sources include pre-recorded NAND-flash synthesised voice (for floor announcements), line-level audio from building PA system (via travelling cable pair), and intercom audio from the emergency communication device. Sound pressure level in the cabin must reach ≥65 dB(A) at 1 m for voice intelligibility. The speaker and amplifier must be rated for the operating temperature range (−20°C to +60°C) and elevator vibration environment.